EasyTon IOP Tonometer — Pen-Style Transpalpebral Applanation Overview Supportive/Benefit-Focused How It Works Position rod gently on closed upper eyelid. Activate measurement; device generates ~100 micro-vibrations per reading to minimize corneal thickness and biomechanical bias. Average IOP displayed in mmHg on LCD. What’s Included Indications for Use Contraindications Key Features Technical Specifications Performance Evidence Category Warranty Shipping Assembly/Use
Pen-style intraocular pressure (IOP) tonometer for fast, reproducible, stress-free screening and monitoring. Transpalpebral, cornea-sparing measurement via vibrational micro-applanation delivers Goldmann-comparable results without anesthetic, fluorescein, or corneal contact. FDA 510(k) cleared (K190382) for professional use in glaucoma care and broader ocular diagnostics.
No corneal touch → reduced contamination and irritation risk, no contact lens removal. Two-second acquisition with automatic averaging in mmHg. Suited to pediatrics, post-operative cases (including KPro), and field care. Galvanic measuring tip improves durability and long-term precision. Minimal training; consistent results at the point of care.
• EasyTon IOP Tonometer (pen device)
• User manual
• Glaucoma diagnosis and monitoring; ocular hypertension/hypotension
• Post-LASIK/refractive surgery assessment
• KPro and artificial cornea follow-up
• Retina, tumor, and trauma cases where corneal contact is undesirable
• Pediatric ophthalmology
• Off-road/field ophthalmology and routine IOP tonometry
• Upper eyelid deformity, scars, inflammation, or other pathology preventing proper placement
• Conjunctival/scleral disorders that vibration may aggravate
• Inability to sit upright during measurement (e.g., early post-op, severe spine/bone disease)
• Post-stroke or neurological conditions interfering with cooperation
• Eyes with altered biomechanical properties from recent surgery or procedures as specified by the manufacturer
• Transpalpebral vibrational applanation; no corneal anesthesia or dye
• ~2 s total measurement time; automatic averaging
• No consumables; contact lenses may remain in place
• Works in postoperative, pediatric, and complex corneal scenarios
• Galvanic measuring tip for extended service life
• Measurement unit: mmHg
• Range: 7–50 mmHg
• Accuracy: ±2 mmHg (7–23), ±5 mmHg (23–50)
• Coefficient of variation: ≤8.1%
• Display resolution: 1 mmHg; LCD
• Max diagnostics time: 2 s
• Power: 2× AAA (1.5 V) batteries; max during procedure 100 mA
• Dimensions: 173 × 27 × 21 mm
• Weight: 88 g (with batteries)
• Operating conditions: +10°C to +35°C; RH ≤80%; pressure 630–800 mmHg
• Storage: −50°C to +40°C; RH ≤98% at +25°C
• Service life: 5 years
• Clearance: FDA 510(k) K190382
Accuracy, reproducibility, and repeatability validated in studies versus the Goldmann reference; clinical performance shown comparable to intracameral methods.
Tonometer
Standard manufacturer warranty.
Processing 0–5 business days; typical delivery within 20 days of order confirmation.
No assembly. Insert batteries, place rod on eyelid, press to measure, read mmHg.

Easyton IOP Tonometer – Eye
UGC FFS-RCV-EZT-04
par ALMAGIA
Prix d'origine
$2,900.00
-
Prix d'origine
$2,900.00
Prix d'origine
$2,900.00
$2,900.00
-
$2,900.00
Prix actuel
$2,900.00
Why Choose Fit Form Studio?
✓ Free Shipping on all orders
✓ 2-Year Warranty – included with your purchase
✓ Need Help? – Call us at (202) 713-9608